Small Heat Treatment Units
Realize every application shortly with compact heat treatment units.
THERMOPROZESS Heat Treatment Units - Mobile & Reliable
THERMOPROZESS heat treatment units are compact, portable units that includes power source, temperature measuring-, control-, and registration equipment. Our units have proven themselves under difficult conditions on construction sites and in construction plants all over the world. The units are characterized by ease of use, versatility and reliability and they are on the state of the art.
The small heat treatment units in ratings of 3 kW and 9 kW have variable secondary voltages. This is an ideal solution for your small preheat and PWHT-operations. Regardless whether repairs or needed during manufacturing.
THERMOPROZESS heat treatment units can be used in all areas of heat treatment.
mobile, rugged, splash-proof housing
- forced-cooled power unit
- power ratings of 3 kW and 9 kW
- stepless voltage (0 to 60 V)
- temperature recording via temperature-printers
- temperature control by automatic program controller
Small Heat Treatment Units | |
Discription | Ref.-No. |
Small Heat Treatment Unit Typ 3 kW | 1010101 |
Small Heat Treatment Unit Typ 9 kW | 1090303 |
3 kW heat treatment unit, technical data |
||
Width |
255 |
mm |
Height |
335 |
mm |
Depth |
485 |
mm |
Weight approx. |
12 |
kg |
Rating at 100% d.c. |
3 |
kW |
Input voltage |
230 |
V |
Output voltage, variable up to |
60 |
V |
Control circuits |
1 |
piece |
Current max. / control circuit |
47 |
A |
Programm controller T144 |
1 |
piece |
Technical details are subject to change
9 kW heat treatment unit, technical data |
||
Width |
255 |
mm |
Height |
675 |
mm |
Depth |
485 |
mm |
Weight ca. |
28 |
kg |
Rating at 100% d.c. |
9 |
kW |
Input voltage |
230 |
V |
Output voltage, variable up to |
60 |
V |
Control circuits |
3 |
pieces |
Current max. / control circuit |
47 |
A |
Programm controller T144 |
3 |
pieces |
Temperature recorder |
1 |
piece |
Measuring range |
0-900 |
°C |
Accuracy, standard |
0,5 |
|
Alternatively available |
0,1 |
|
Technical details are subject to change