Heat Treatment Units Series TA

Realize every application shortly with compact heat treatment units. 

THERMOPROZESS Heat Treatment Units - Mobile & Reliable

THERMOPROZESS heat treatment units are compact, portable units that include the power source and the necessary devices for the implementation of the measurement, control and register. They have proven themselves under difficult conditions on construction sites and in factories. The thyristor-controlled TA-Units in its power outputs 48 kW, 60 kW, 72 kW, 84 kW and 108 kW have an infinitely-adjustable secondary voltage of 0V up to 84V and are therefore adaptable to the varied heat treatment tasks. This makes the TA-series the ideal solution for all heat treatment tasks. The units are characterized by ease of use, versatility and reliability and they are on the state of the art. Due to the high diversity of the THERMOPROZESS heat treatment units, they can be used in all areas of heat treatment.

State oft he art

Take advantage of our new, modern touch panel (P600 ) controlled systems. These have a huge number of advantages, such as the welder traffic light that allows the welders on site, by a single glance, to stay within the temperature tolerances, which is inevitable for modern steels. Alternatively, our units can also be equipped with separate controllers (T144). All units are equipped with 6-channel analog-printers, but can be equipped with state of the art and tamper-proof digital temperature-recording devices.

 

  • mobile, rugged, splash-proof housing
  • forced-cooled three-phase transformer
  • power ratings from 48 kW up to 108 kW
  • thyristor-regulated variable secondary voltage (0-84V)
  • temperature recording via temperature-recorder
  • temperature control by automatic program controller/touch panel
  • special functions for third parties (eg welders traffic light)

 

Heat Treatment Units Series TA
Discription   Ref.-No.  
Heat Treatment Unit Typ   48 kW 1048062
Heat Treatment Unit Typ   60 kW 1060062
Heat Treatment Unit Typ   72 kW 1072062
Heat Treatment Unit Typ   84 kW 1084122
Heat Treatment Unit Typ 108 kW 1108122
Heat Treatment Unit Typ 144 kW 1108122

 

 

 

48 kW heat treatment unit

Width

985

mm

Height

1400

mm

Depth

700

mm

Weight approx.

460

kg

Rating at 100% d.c.

48

kW

Primary voltage

400 / 500

V

Primary current

69 / 55

A

Secondary voltage

0 up to 84

V

Control circuits

6

pieces

Current max. / control circuit

95

A

Programme controller T144

6

pieces

Temperature recorder

1

piece

Measuring range

0 - 900

°C

Accuracy, standard

0,5

 

Alternatively available

0,1 

 

Technical details are subject to change

60 kW heat treatment unit

Width

985

mm

Height

1400

mm

Depth

700

mm

Weight approx.

370

kg

Rating at 100% d.c.

60

kW

Primary voltage

400 / 500

V

Primary current

86 / 69

A

Secondary voltage

0 up to 84

V

Control circuits

6

pieces

Current max. / control circuit

120

A

Programme controller T144

6

pieces

Temperature recorder

1

piece

Measuring range

0 - 900

°C

Accuracy, standard

0,5

 

Alternatively available

0,1 

 

Technical details are subject to change

72 kW heat treatment unit

Width

985

mm

Height

1400

mm

Depth

700

mm

Weight approx.

470

kg

Rating at 100% d.c.

72

kW

Primary voltage

400 / 500

V

Primary current

104 / 83

A

Secondary voltage

0 up to 84

V

Control circuits

6

pieces

Current max. / control circuit

143

A

Programme controller T144

6

pieces

Temperature recorder

1

piece

Measuring range

0 - 900

°C

Accuracy, standard

0,5

 

Alternatively available

0,1 

 

Technical details are subject to change

84 kW heat treatment unit

Width

985

mm

Height

1400

mm

Depth

700

mm

Weight approx.

553

kg

Rating at 100% d.c.

84

kW

Primary voltage

400 / 500

V

Primary current

121 / 97

A

Secondary voltage

0 up to 84

V

Control circuits

12

pieces

Current max. / control circuit

85

A

Programme controller T144

12

pieces

Temperature recorder

2

piece

Measuring range

0 - 900

°C

Accuracy, standard

0,5

 

Alternatively available

0,1 

 

Technical details are subject to change

108 kW heat treatment unit

Width

985

mm

Height

1400

mm

Depth

700

mm

Weight approx.

500

kg

Rating at 100% d.c.

108

kW

Primary voltage

400 / 500

V

Primary current

156 / 124

A

Secondary voltage

0 up to 84

V

Control circuits

12

pieces

Current max. / control circuit

107

A

Programme controller T144

12

pieces

Temperature recorder

2

piece

Measuring range

0 - 900

°C

Accuracy, standard

0,5

 

Alternatively available

0,1 

 

Technical details are subject to change

144 kW heat treatment unit

Width

985

mm

Height

1400

mm

Depth

700

mm

Weight approx.

580

kg

Rating at 100% d.c.

144

kW

Primary voltage

400 / 500

V

Primary current

208 / 166

A

Secondary voltage

0 up to 84

V

Control circuits

12

pieces

Current max. / control circuit

143

A

Programme controller T144

12

pieces

Temperature recorder

2

piece

Measuring range

0 - 900

°C

Accuracy, standard

0,5

 

Alternatively available

0,1 

 

Technical details are subject to change

 
topMobileversion