Heat Treatment Units Series ECO

Realize every application shortly with compact heat treatment units. 

THERMOPROZESS Heat Treatment Units - Mobile & Reliable
THERMOPROZESS heat treatment units are compact, portable units that include the power source and the necessary devices for the implementation of the measurement, control and register. They have proven themselves under difficult conditions on construction sites and in factories. The low-cost ECO-units in its outputs of 48 kW, 60 kW, 72 kW, 84 kW, 108 kW and 144 kW have secondary output voltages of 0V, 30V and 65V. This makes the ECO series the ideal solution for easy and fast post weld heat treatment (PWHT) and pre-heatings. The units are characterized by ease of use, versatility and reliability and they are on the state of the art. THERMOPROZESS heat treatment units can be used in all areas of heat treatment.


  • mobile, rugged, splash-proof housing
  • forced-cooled three-phase transformer
  • power ratings from 48 kW up to 144 kW
  • fixed voltage (0/30/65 V)
  • temperature recording via temperature-printers
  • temperature control by automatic program controller
  • Master / slave circuit of the program controller
  • Alarm sirens

 

Heat Treatment Units Series ECO
Discription   Ref.-No.  
Heat Treatment Unit Typ   48 kW 1048061
Heat Treatment Unit Typ   60 kW 1060061
Heat Treatment Unit Typ   72 kW 1072061
Heat Treatment Unit Typ   84 kW 1084121
Heat Treatment Unit Typ 108 kW 1108121
Heat Treatment Unit Typ 144 kW 1108121

 

 

 

48 kW heat treatment unit, technical data

Width

870

mm

Height

1310

mm

Depth

700

mm

Weight approx.

360

kg

Rating at 100% d.c.

48

kW

Primary voltage

400 / 500

V

Primary current

70 / 55

A

Secondary voltage

0 – 30 – 65

V

Control circuits

6

pieces

Current max. / Control circuit

125

A

Programme controller

6

pieces

Temperature recorder

1

piece

Measuring range

0 – 900

°C

Accuracy, standard

0,5

 

Alternatively available

0,1

 

Technical details are subject to change

60 kW heat treatment unit, technical data

Width

870

mm

Height

1310

mm

Depth

700

mm

Weight approx.

375

kg

Rating at 100% d.c.

60

kW

Primary voltage

400 / 500

V

Primary current

86 / 70

A

Secondary voltage

0 – 30 – 65

V

Control circuits

6

pieces

Current max. / Control circuit

180

A

Programme controller

6

pieces

Temperature recorder

1

piece

Measuring range

0 – 900

°C

Accuracy, standard

0,5

 

Alternatively available

0,1

 

Technical details are subject to change

72 kW - 6 cc heat treatment unit, technical data

Width

870

mm

Height

1310

mm

Depth

700

mm

Weight approx.

390

kg

Rating at 100% d.c.

72

kW

Primary voltage

400 / 500

V

Primary current

104 / 84

A

Secondary voltage

0 – 30 – 65

V

Control circuits

6

pieces

Current max. / Control circuit

180

A

Programme controller

6

pieces

Temperature recorder

1

piece

Measuring range

0 – 900

°C

Accuracy, standard

0,5

 

Alternatively available

0,1

 

Technical details are subject to change

72 kW - 12 cc heat treatment unit, technical data

Width

870

mm

Height

1310

mm

Depth

700

mm

Weight approx.

400

kg

Rating at 100% d.c.

72

kW

Primary voltage

400 / 500

V

Primary current

104 / 84

A

Secondary voltage

0 – 30 – 65

V

Control circuits

12

pieces

Current max. / Control circuit

90

A

Programme controller

12

pieces

Temperature recorder

2

piece

Measuring range

0 – 900

°C

Accuracy, standard

0,5

 

Alternatively available

0,1

 

Technical details are subject to change

84 kW heat treatment unit, technical data

Width

870

mm

Height

1310

mm

Depth

700

mm

Weight approx.

420

kg

Rating at 100% d.c.

84

kW

Primary voltage

400 / 500

V

Primary current

121 / 97

A

Secondary voltage

0 – 30 – 65

V

Control circuits

12

pieces

Current max. / Control circuit

125

A

Programme controller T144

12

pieces

Temperature recorder

2

pieces

Measuring range

0 – 900

°C

Accuracy, standard

0,5

 

Alternatively available

0,1

 

Technical details are subject to change

108 kW heat treatment unit, technical data

Width

870

mm

Height

1310

mm

Depth

700

mm

Weight approx.

525

kg

Rating at 100% d.c.

108

kW

Primary voltage

400 / 500

V

Primary current

156 / 125

A

Secondary voltage

0 – 30 – 65

V

Control circuits

12

pieces

Current max. / Control circuit

135

A

Programme controller T144

12

pieces

Temperature recorder

2

pieces

Measuring range

0 – 900

°C

Accuracy, standard

0,5

 

Alternatively available

0,1

 

Technical details are subject to change

144 kW heat treatment unit, technical data

Width

870

mm

Height

1310

mm

Depth

700

mm

Weight approx.

630

kg

Rating at 100% d.c.

144

kW

Primary voltage

400 / 500

V

Primary current

208 / 199

A

Secondary voltage

0 – 30 – 65

V

Control circuits

12

pieces

Current max. / Control circuit

180

A

Programme controller T144

12

pieces

Temperature recorder

2

pieces

Measuring range

0 – 900

°C

Accuracy, standard

0,5

 

Alternatively available

0,1

 

Technical details are subject to change

 
topMobil